Deng Yun Chenaand Michael Ostermana
a CALCE, Center for Advanced Life Cycle Engineering, Department of Mechanical Engineering, University of Maryland, College Park, Maryland 20740, USA
Abstract:
Due to the Restriction of Hazardous Substances by
European legislation, Lead free solders such as SAC305 have
replaced the use of lead in the commercial electronic industry.
Lead free (LF) solder joints, having lower ductility, often are the
victims of early failures due to drop events. To improve the drop
impact reliability of lead free solder joint, underfill and corner
staking were apply to the packages. While, numerous literatures
reported that underfill can mitigate the drop reliability, limited
corner staking studies have been reported in which most focused
on the mitigating the drop impact with corner staking. This
paper presents the reliability assessment of corner-staked
packages under temperature cycling, harmonic vibration, and
drop impact. The test results show that corner staking not only
improves the drop impact reliability of surface mount parts but
also improves the reliability of parts under vibration and
temperature cycling.
Keywords: Drop test, Corner staking, Temperature cycling, vibration, drop test, Solder joint, Weibull, ALT, Testing