Development of an Alternative Wire Bond Test
P. Lall, M. Pecht, and D. Barker
An alternative test technique to the wire bond pull test is presented
for wire bond interconnects. The new test technique based on electromagnetic
resonance, has the potential for on-line use as a quality assurance and
operational life evaluation method. The new technique greatly reduces the
test time in comparison to the existing MIL-STD-883 pull test and internal
visual inspection. This new test technique more closely simulates the operational
stress than the wire bond pull test and has also shown a sensitivity to
defects including ball off pad, shallow stamps at stitch bonds, and small
ball bonds. The sensitivity of the test technique in terms of different
failure signature for various failure modes has also been demonstrated.
Full
article in .pdf format (Adobe Acrobat required) is available to CALCE
Consortium members.
© IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.